2013年10月24日星期四

How to correctly judge the photoelectric sensor output no signal

Photoelectric sensor is a photoelectric sensor element as a sensing element , widely used in the automation field . Photoelectric sensors for material handling, error detection , process manufacturing automation, object detection can also be used over long distances or fault is detected. Photoelectric sensors detect the distance of the object has a unique advantage , but in the specific use of the environment, there will be some technical problems , which we need methodical technical judgment. In the application of photoelectric sensors to detect objects in the distance , a lot of users will encounter problems when using photoelectric sensors to detect objects is no output signal after , making it impossible for subsequent data analysis. Most people see no signal sensor output may often be some wrong judgment , such as some people on the direct determination of Shaft Position Sensor bad reason. But the reason is not all like that, photoelectric sensor detects an object after no output , there may be many reasons , we need to do it step by step investigation . The first thing to consider is wiring or configuration problems . For beam photoelectric sensor must be cast by the light unit and a light unit used in combination with both ends requires power ; while retroreflective Engine Temperature Sensor probe and must be retroreflective sheeting used in combination ; same time, the user must provide a stable power supply to the sensor , if it is DC power supply , you must confirm the positive and negative , should the positive and negative connection error will cause the output signal is not . The reason analysis is to consider Camshaft Position Sensor itself , we also need to consider the problem is to detect the location of objects , if the detected object is not in the detection area , so that the detection is futile. Test object must be detected in the sensor area , that is, can sense the optical range. Secondly, we must consider the optical axis of the sensor there is no alignment problem , on the radio type of light-emitting portion and a light receiving unit must be aligned with the optical axis , the corresponding portion of the retroreflective type sensor must be aligned with the optical axis and the reflector . The same should also consider whether the detected object is the standard sensing object or minimum standard sensing object , object detection can not detect an object less than the minimum standard , thus avoiding lead shot , reflective not well detect transparent objects , like a reflection on detecting the color of objects is required, the deeper the color , the more recent detection distance . If the above conditions can be excluded to make it clear , we need to do is to detect environmental disturbances . Such as light intensity can not exceed the rated range ; if there is dust environment of the scene , we need our regular cleaning optical sensor probe surface ; or more sensors close fitting , mutual interference ; there is a relatively large impact that electrical interference , if surrounded power equipment , interference must have the appropriate anti-jamming measures . If you have done the above one by one investigation , these factors can be explicitly excluded or no signal output , it is recommended to return factory testing to determine .

没有评论:

发表评论